TS-Auto

TS-Auto
Fully automated, coagulation system with STAT capability

  • Bi-directional LIS
  • 6 measuring channels
  • On Board reagent cooling system
  • Closed-system reagents and cuvettes with RFID tracking

Throughput:
up to 90 test/hour (PT), 60 test/hour (PT and APTT run simultaneously), 20 test/hour (D-Dimer)

Measuring Principals:
Clotting 660nm, Chromgenic 405nm, Immunologic 575nm

Sample Type:
Plasma

Programing:
User defined profiles and calculation, method defined washing programs

Parameters:
PT, TT, FIB, APTT, D-Dimer, AT3, FDP, LA1, LA2, FII, FV, FVII, FVIII, FIX, FX,FXI, PCco, PCch, PS, a2-AP, Plg. Unlimited customer parameters can be added.


Reagent/Sample Handling
Reagent Tray:
13 positions (1 for cleaning solution)

Sample Rack:
14 positions

Sample Volume:
5µl , 1µl increments

Reagent Volume:
8ml maximum

Sample/Reagent Probe:
Liquid Level Detection, Collision protection, . Reagent Volume Check, Sample/Reagent Pre-Heating 37C

Probe Cleaning:
Interior and exterior automatic probe washing, Carry-Over < 2%

Waste:
Onboard waste collection

Reaction System
Reaction Area
4 clotting 660nm, 1 Immunologic 575nm, 1 Chromogenic 405nm
Measurment Methods:
660nm scattered light detection, 405nm colorimetric, 575nm turbidimetric
Cuvette: Optical Length 5mm
Reaction Volume: 150 - 400µl
Operating Temperature: 37°C
Temperature Fluctuation: ± 0.1C
Mixing Shaker style, dedicated mixer
Cuvette Capacity: 63
Incubation: 4 wells 37°C

Optical System
Light Source: LED
Wavelength: 405nm, 575nm, 660nm

Control and Calibration
Calibration Mode: Manual and auto
Calibration calculation methods: Linear Regression, Broken-line Regression, Double Logarithmic Linear Regression, Double Logarithmic Broken-line Regression
Quality Control: 30 files, Levy-Jennings, automatic entery of ranges with barcode
Auto QC function:


Software
LIS Bi-Directional, HL7 Protocol, Patient Results Only
Languages English, Spanish, Russian, Ukrainian
Data Storage 150 000
Alerts: Full cuvette and water Waste Container, Sample Volume, Reagent Volume, Empty water container, Cuvette quantity
Printing Internal Printer, External Printer available on any Windows compatible Printer
Statistics Calculation of QC mean, SD and %CV
Re-Run Manual
Dilution Automatic Sample Dilution

Hardware
Display: 10.4" Color LCD touch screen 800x600
Barcode reader: Internal for samples, external USB
Connectivity: 4 USB, 1 LAN

Working Condition
Power Supply 100 ~ 240 VAC, 50/60Hz, 300VA
Temperature 20 ~ 30C
Humidity: 40 ~ 85%
Water Consumption: PT: 30ml per/test, APTT: 48ml per/test, TT 74ml per/test, FIB 71ml per/test, Ddimer: 158ml per/test
Dimension: 40cm x 43cm x 45cm (W x H x D)
Weight: 28kg